Lightweight. Versatile. Superior Sound Retention. These are characteristics Lite-Deck can offer. Lite-Deck is the solid concrete alternative for conventional floor and deck applications in residential homes, commercial buildings, and safety structures. The results? A quiet, secure concrete structure that is sustainable and energy-efficient.

 

SPECIFICATIONS

The Lite-Deck Technical Evaluation Report is available for download. This manual contains a complete technical review of the Lite-Deck system, including: structural and properties tests, autocad drawings, and engineering details.

This Evaluation is also available in a binder publication.
Please email general@liteform.com for a copy of this publication.

Span Tables

These span charts are PDF documents and can be downloaded and viewed with Adobe Acrobat Reader.
If you are having problems opening the following file please click the link and download the reader free of charge.
Adobe Acrobat Reader.

pdfLITE-DECK SPAN CHARTS (384k)

General Specifications
6-inch Base Section – EPS Insulation with continuous interlocking edges and load-bearing beam cavity every 24-inches
Top Hat Sections – 16” X 48” X 2”, 4” or 6” depths. EPS Insulation with self-aligning edges
Steel Stiffeners – Continuous 18-gauge steel channel every 12-inches
Transverse Load (Shoring) – ASTM E72-05 Test – Shore in accordance with latest edition of ACI347R.
Concentrated (Temporary) Load – ASTM E661-03 Test – Load in accordance with ASTM Standards.
Maximum Ceiling Load (Channel Withdrawal) – RAD-3862 Test – Safe fastening load is 128 lbs. per lineal foot or 64 lbs. per square foot.  
Fire Resistance Rating – ASTM E 119-00 Test – 1.5 hour rating with 250 lb. per square foot load.
Fire Performance Evaluation (w/1/2 inch Drywall) – UBC 26-3 Test – Passed acceptance criteria.
Fire Performance Evaluation (w/out 1/2 inch Drywall) – UBC 26-3 Test – Passed acceptance criteria.
STC (Sound Transmission Class) – STC 57 by Field Test – 14” concrete joist including 3” concrete cover.
IIC (Impact Isolation Class) –
IIC 44 by Field Test – 14” concrete joist including 3” concrete cover.
IIC 82 by Field Test – 14” concrete joist including 3” concrete cover and 1/2" Carpet w/Pad.  
R-Value – C177 or C518 Test – Overall R-26.4 for 6” Base Section. R-4.40 per inch of Insulation.

 

 

DESCRIPTION
AUTOCAD
PDF
LITE-DECK TECH EVALUATION MANUAL:

1.7 MB

pdf
ALL LITE-DECK DETAIL DRAWINGS
ldspecs
pdf
6" x 2' Lite-Deck
ldspecs
pdf
6" x 4' Lite-Deck
ldspecs
pdf
8" x 2' Lite-Deck
ldspecs
pdf
10" x 2' Lite-Deck
ldspecs
pdf
12" x 2' Lite-Deck
ldspecs
pdf
2" Top Hat
ldspecs
pdf
4" Top Hat
ldspecs
pdf
6" Top Hat
ldspecs
pdf
Top Hat Combinations
ldspecs
pdf
Fire Rating Evaluation
2 MB
pdf
Sound Transmission Rating
1 MB
pdf


EPS Property Units ASTM Test    
Thermal Conductivity "K Factor" BTU/(hr) (sqft)(°F) C177 of C518 @25 °F 0.227
@40 °F 0.238
@75 °F 0.263
Thermal Resistance "R Value" One inch thickness C177 or C518 @25 °F 4.40
@40 °F 4.20
@75 °F 3.80
Compressive Strength psi D1621 @10% 13
Flexural Strength psi C203 @5% 32
Tensile Strength psi D1623   17
Shear Strength psi D732   23
Water Vapor Permeance, max. Perm. ng/Pam² E 96   3.5
Absorption by Volume, max. % C272   <3.0
Capillarity       none
Coeff. Of Thermal Expansion in/(in)(°F) D696   0.000035
Max. Service Temperature °F   Long-Term 167
Intermittent 180
Flame Spread max. thickness 6"   UL@(BRYX)   <20
Smoke Development   UL@(BRYX)   <300
(1) All values shown are representative values for one inch (1") thick material based on data from Huntsman Chemical Corporation, Styrochem International, NOVA Chemical Corporation and BASF Corporation. Specifications Reference ASTM C578-00. (2) Federal Trade Commission Ruling: Use the 75 °F R-value when calculating R-Values for residential construction. (3) Value at yield or 10% which ever comes first. (4) Value at yield or 5% which ever comes first. (5) Do not expose EPS to open flames or other direct or indirect high temperature ignition sources. Failure to comply may result in personal injury or property damage.

 